PACKING FOR HIGH TEMPERATURE PUMPS
Comparative Gaskets for High Temperature Pumps
Packing | Temperature (ºC) | pH |
MG 410 | 550 | 0-14 |
MG 420 | 600 | 0-14 |
MG 520 | 700 | 0-14 |
MG 780 | – 200/650 | 0-14 |
MG 980 | 600 | 0-14 |
MG 970 | 500 | 0-14 |
Packing | Pressure (Bar) | ||
in Valve | in Pump | on Axis | |
MG 410 | 200 | 100 | 50 |
MG 420 | 200 | 100 | 50 |
MG 520 | 200 | 100 | 50 |
MG 780 | 310 | 50 | 20 |
MG 980 | 200 | 75 | 35 |
MG 970 | 200 | 75 | 35 |
Packing | Speed (m / s) | ||
in Valve | in Pump | on Axis | |
MG 410 | 1,5 | 1,5 | 20 |
MG 420 | 1,5 | 2 | 25 |
MG 520 | 1 | 3 | 50 |
MG 780 | 0.5 | 1 | 10 |
MG 980 | 1,5 | 2 | 30 |
MG 970 | 1,5 | 2 | 30 |